Testing the applicability of a non-contact IR thermometer for wall surface temperature measurements in a cave environment: A case study from the dynamic Císařská Cave (Moravian Karst)
DOI:
https://doi.org/10.3986/ac.v55i1.14730Keywords:
cave airflow, Císařská Cave, non-contact IR thermometer, temperature calibration, wall surface temperatureAbstract
The surface temperature of cave walls is important, particularly as a factor controlling water condensation and calcite corrosion, as well as in paleoclimatic reconstructions of external annual temperatures. The use of a non-contact IR thermometer (NCT) could provide an alternative method for monitoring wall surface temperature in inaccessible passages of the cave. However, temperatures obtained by the standard NCT showed increased error. The accuracy of the NCT was tested by comparison with a calibrated contact thermometer (CCT), which revealed a systematic error of –8.2 ± 1.2 °C for the right wall and –8.3 ± 0.9 °C for the left wall. Calibration with the equations T = 0.478×NCT + 8.254 (right wall) and T = 0.554×NCT + 8.308 (left wall) corrected this error. Uncertainty was tested by repeated measurements on a calibration area of 1.7 m2 in the cave, resulting in a random relative error of 4.25 % for dry wall surfaces and 4.95 % for wet wall surfaces. Although a relative error of 5 % is common for major instrumental methods, it is near the applicability limit for karstological interpretations.
Downloads
Downloads
Published
How to Cite
Issue
Section
License

This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors guarantee that the work is their own original creation and does not infringe any statutory or common-law copyright or any proprietary right of any third party. In case of claims by third parties, authors commit their self to defend the interests of the publisher, and shall cover any potential costs.
More in: Submission chapter